Thermo Scientific™ TSX Series Ultra-Low Freezers
GREENER_CHOICEBIOPHARMA

Thermo Scientific™ TSX Series ultra-low freezers are designed to meet the highest sustainability, temperature management and reliability standards for -80°C and -70°C storage.

£16612.80 - £20850.77

Specifications

Type Ultra-Low Freezer, Upright
Temperature Range -50°C to -86°C
Insulation Vacuum Insulation Panels (VIP) + Water-Blown Polyurethane Foam (SNAP-compliant)
Interior Stainless Steel
Shelves 3
View More Specs

Products 4
Product Code Brand Holds Dimensions (DxWxH) Exterior Electrical Requirements Rack Capacity Price Quantity & Availability  
Product Code Brand Holds Dimensions (DxWxH) Exterior Electrical Requirements Rack Capacity Price Quantity & Availability  
15768587
GREENER_CHOICEBIOPHARMA
View Documents Promotion Details
Thermo Scientific™
2 in. Boxes (400) 37.6 x 28.3 x 78 in. (95.5 x 71.9 x 198.1 cm) 230 V 50 Hz 16
£16612.80
Each
Please to purchase this item. Need a web account? Register with us today!
15778587
GREENER_CHOICEBIOPHARMA
missing translation for 'viewDocuments' Promotion Details
Thermo Scientific™
2 in. Boxes (500) 37.6 x 34.0 x 78 in. (95.5 x 86.4 x 198.1 cm) 230 V 50 Hz 20
£17884.20
Each
Please to purchase this item. Need a web account? Register with us today!
15788587
GREENER_CHOICEBIOPHARMA
missing translation for 'viewDocuments' Promotion Details
Thermo Scientific™
2 in. Boxes (600) 37.6 x 39.6 x 78 in. (95.5 x 100.6 x 198.1 cm) 230 V 50 Hz 24
£19155.58
Each
Please to purchase this item. Need a web account? Register with us today!
15798587
GREENER_CHOICEBIOPHARMA
missing translation for 'viewDocuments' Promotion Details
Thermo Scientific™
2 in. Boxes (700) 37.6 x 45.2 x 78 in. (95.5 x 114.8 x 198.1 cm) 230 V 50 Hz 28
£20850.77
Each
Please to purchase this item. Need a web account? Register with us today!
Description

Description

The ENERGY STAR™ certified Thermo Scientific™ TSX Series ultra-low freezers are designed to meet the highest standards in reliability, sustainability and temperature management. At the heart of the TSX Series is V-drive technology, designed to adapt to user patterns, substantially reducing energy and HVAC costs without compromising performance. All TSX Series freezers are manufactured in a zero-waste facility and are built with natural refrigerants and water-blown foam insulation, compliant with the U.S. EPA's Significant New Alternatives Policy (SNAP), the European Union's F-Gas compliance and other sustainability standards.

From our first ULT freezer in 1940 to today, the combined experience of REVCO, Forma Scientific, Jewett, Harris, and other families of products continues to drive our ability to deliver industry-leading innovations that help accelerate science and health care.

Performance
  • No need to worry about where your samples are stored within the freezer.  With peak variation less than 5°C, your samples are protected and safely stored throughout the entire cabinet space. *
  • Long warm-up time from -50°C to -80°C: 5.05 hours*
  • Quiet enough to reside directly in the laboratory, rather than in the hall. At just 45.5 dBA, the TSX Series’ sound level is comparable to a home refrigerator.*
  • V-drive’s adaptive control is designed to detect usage patterns such as door openings when a higher compressor speed is needed and periods of stability where the compressor runs at a lower speed, saving energy without compromising protection

Wireless Monitoring Solution

Thermo Scientific™ DeviceLink™ comes embedded in your ULT freezer  providing real-time monitoring of system status and sample temperature.
  • View critical lab equipment data and equipment notifications on your mobile and web applications.
    • Display temperature
    • Ambient temperature
    • Alarm and alerts notification
  • Access data anytime, anywhere—data and alarms from monitored lab equipment are securely stored on the Cloud and sent to the user via email and mobile-phone notifications
  • InstrumentConnect™ streamlined dashboard-style reporting reduces time spent interpreting data
  • Unlike traditional connectivity methods, DeviceLink™ operates on a client-cloud architecture, requiring minimal IT support
  • No need to install sensors—the only plug-in is the equipment data port to read the parameters directly from the factory-installed sensors
  • Applicable Networks: WPA2-PSK, WPA-PSK, WEP, WPA2-EAP-PEAP, WPA-EAP-PEAP
User Friendly
  • Newly re-designed touch-screen user interface with easy-to-use: set-up wizard, event log, temperature mapping and data downloads via a built-in USB port
  • Eliminate the need for a separate chart recorder with the touch-screen’s datalogging and temperature mapping features, all exportable via a built-in USB port
  • Ergonomic design including comfortable door handle, eye-level touch-screen and shelf-level placement that don’t require floor-level loading of racks
  • Four capacities (400, 500, 600 and 700 2-inch box) to accommodate a variety of storage needs and lab footprint specifications
  • Compatible with most racking systems including a full range of Thermo Scientific™ racks for boxes, microplates, Thermo Scientific™ Matrix™ and Nunc CryoBank™ tubes
  • Security features including alarm settings, padlock-compatible doors and optional access card entry

Sustainability
  • Completed the ACT Environmental Impact Factor Label labeling process, a third party–verified information about the environmental impact of laboratory products.
  • TSX ULT portfolio is ENERGY STAR™ certified providing significantly increased energy savings and decreased operational costs
  • Natural refrigerants and water-blown foam insulation, making the TSX Series compliant with the U.S. Environmental Protection Agency’s Significant New Alternatives Policy (SNAP), the European Union’s F-Gas and other sustainability standards
  • Manufactured in an award-winning, zero-waste to landfill facility
  • Lower HVAC costs as a result of less heat emission into the environment
  • Upon receiving the unit, we advise you to properly dispose of any packaging material, used to secure the unit during the shipping process.  Please refer to local recycling codes and dispose of any materials accordingly.  For information on waste disposal sites, please refer to your local waste provider.

Footnotes:
* Typical freezer data based on internal testing with freezer setpoint at -80°C and ambient temperature at 20°C. Performance data varies across freezer size and electrical specifications.

Performance Data*:

  High Performance Mode Standard Mode    
 Model Energy ConsumptionPeak Variation from Setpoint Energy Consumption 2Peak Variation from Setpoint 2Sound1-min Door Opening Recovery to -75°CWarm Up Time (-80°C to -50°C)ENERGY STAR
UOM(kW-hr/day)(°C)(kW-hr/day)(°C)(dBa)(min)(min)(kW-hr/day cuft)
 TSX40086A 8.5 +8.2 / +0.2 10.7 +5.0 / -1.8 49.8 21 292 0.492
 TSX40086D 7.7 +7.5 / +0.5 9.9 +4.7 / -2.1 49.8 19 292 0.492
 TSX40086V 7.7 +7.5 / +0.5 9.9 +4.7 / -2.1 49.8 19 292 0.492
 TSX50086A 8.7 +8.0 / -0.1 11.4 +4.9 / -2.0 50.0 24 264 0.448
 TSX50086D 8.5 +8.6 / +0.2 10.8 +4.5 / -2.4 50.0 26 264 0.425
 TSX50086V 8.5 +8.6 / +0.2 10.8 +4.5 / -2.4 50.0 26 264 0.425
 TSX60086A 9.4 +8.0  /+1.9 11.5 +4.8 / -0.7 49.4 31 297 0.395
TSX60086D 8.6 +7.6 / +1.8 11.1 +4.5 / -0.3 49.4 31 297 0.336
TSX60086V 8.6 +7.6 / +1.8 11.1 +4.5 / -0.3 49.4 31 297 0.336
TSX70086A 10.2 +6.7 / +2.0 13.5 +4.8 / -1.0 48.6 29 339 0.359
TSX70086D 9.4 +7.4 / +2.0 12.7 +3.8 / -1.5 48.6 34 339 0.359
TSX70086V 9.4 +7.4 / +2.0 12.7 +3.8 / -1.5 48.6 34 339 0.359



Specifications

Specifications

Ultra-Low Freezer, Upright
Vacuum Insulation Panels (VIP) + Water-Blown Polyurethane Foam (SNAP-compliant)
3
Touch-Screen LCD
Warranty varies by country, please contact us for details
37.6 in.
95.5 cm
78 in.
198.1 cm
Alarm, Recorder
Smart-Vue Compatible
R290 (1st stage), R170 + R290 mix (2nd stage)
-50°C to -86°C
Stainless Steel
Upright
TSX Series
Manual
28.3 in.
71.9 cm
51.2 in.
130.1 cm
Thermo Scientific™ DeviceLink™ (Networks: WPA2-PSK, WPA-PSK, WEP, WPA2-EAP-PEAP, WPA-EAP-PEAP)
V-drive
Videos
SDS
Documents

Documents

Certificates

  1. Data is representative of performance and not published product specifications. Results should not be referenced in developing any regulatory parameters for specific customer usage.
  2. Freezer performance will vary based on customer product volume, storage format, operating conditions, test methodology and performing recommended maintenance
  3. Continuous product enhancements may, without notice, result in amendments or omissions to this technical data sheet. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein.