missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ Cytochrome C Human ELISA Kit

For the quantitative detection of human Cytochrome c.

£451.00 - £3070.00

Specifications

Accession Number P99999
Assay Range 0.08-5.0 ng/mL
Assay Sensitivity 0.05 ng/mL
Conjugate Biotin
Product Type ELISA Kit
View More Specs

Includes: Aluminium pouch(es) with a Microwell Plate coated with monoclonal antibody to human Cytochrome c
Biotin-Conjugate anti-human Cytochrome c monoclonal antibody
Streptavidin-HRP
Human Cytochrome c Standard lyophilized, 10ng/mL upon reconstitution
Assay Buffer Concentrate 20x (PBS with 1% Tween 20 and 10% BSA)
Wash Buffer Concentrate 20x (PBS with 1% Tween 20)
Lysis Buffer 10x
Substrate Solution (tetramethyl-benzidine)
Stop Solution (1M Phosphoric acid)
Green-Dye
Red-Dye
Adhesive Films

Products 2
Product Code Brand Quantity Price Quantity & Availability  
Product Code Brand Quantity Price Quantity & Availability  
15561847
View Documents Promotion Details
Invitrogen™
BMS263TEN
10 x 96 Tests
£3070.00
Pack of 10
Estimated Shipment: 23-12-2024
to see stock.
Add to basket
 
15541847
View Documents Promotion Details
Invitrogen™
BMS263
96 Tests
£451.00
96 tests
Estimated Shipment: 10-12-2024
to see stock.
Add to basket
 
Description

Description

The Human Cytochrome c ELISA quantitates Hu cytochrome c in human cell lysates. The assay will exclusively recognize both natural and recombinant Hu cytochrome c. Principle of the method The Human cytochrome c solid-phase sandwich ELISA (enzyme-linked immunosorbent assay) is designed to measure the amount of the target bound between a matched antibody pair. A target-specific antibody has been pre-coated in the wells of the supplied microplate. Samples, standards, or controls are then added into these wells and bind to the immobilized (capture) antibody. The sandwich is formed by the addition of the second (detector) antibody, a substrate solution is added that reacts with the enzyme-antibody-target complex to produce measurable signal. The intensity of this signal is directly proportional to the concentration of target present in the original specimen. Rigorous validation Each manufactured lot of this ELISA kit is quality tested for criteria such as sensitivity, specificity, precision, and lot-to-lot consistency. See manual for more information on validation.

Platinum Kits undergo stringent in-house development, manufacture and quality-validation processes ensuring highest possible product performance and optimal lot-to-lot consistency.
Specifications

Specifications

P99999
0.05 ng/mL
ELISA Kit
Human
Colorimetric Microplate Reader
CYC,HCS,THC4
6%
HRP
Cell Lysate,5 μL
CYC, somatic Cytochrome C, HCS
1 hr. 20 min.
0.08-5.0 ng/mL
Biotin
Cell Lysates
ELISA
54205
4%
Pre-coated 96 well plates, Standard, Sample Diluent, Assay Buffer concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Lysis Buffer, Chromogen, Stop Solution, Controls, Adhesive Plate Covers
RUO
2°C to 8°C
Human
3 hr. 10 min.
Videos
SDS
Documents

Documents

Product Certifications

For Research Use Only