GE Whatman Filtration for HPLC Sample Preparation

Landing_Banner Landing_Banner_Mobile

Accurate. Reliable. Fast

Simplify sample preparation with the Whatman™ regenerated cellulose membrane portfolio from GE Healthcare

  • Reduce cost with well-designed devices – the regenerated cellulose (RC) family includes products for robotic sample handing, outside-of-lab sample preparation, certified method development, and working with hard-to-filter samples.
  • Increase accuracy with reliable, repeatable results – The RC family is demonstrated to have extremely low levels of chemical extractables that could interfere with analysis. Products are available to retain a variety of particle sizes.
  • Save time with multifunctional products – reduce time spent deciding which membrane type to use for your sample preparation. The RC membrane is broadly compatible with common HPLC sample solvents and mobile phases.
  • Improve efficiency with ready-to-use products – RC products are supplied ready for use. The hydrophilic, low-protein binding RC membrane is suitable for a wide variety of HPLC applications.

Characteristics of common membranes

Solvent compatibility

Qualities

Membrane1

Aqueous

Nonaqueous

Low protein binding

Low extractables

RC +++ +++ +++ +++
CA +++ - +++ +
ME +++ + + -
CN +++ - - -
PVDF +++ +++ +++ +
PP +++ +++ - -
NYL +++ + - -
PES +++ + +++ +++
PTFE - +++ - +
Anopore™ +++ + +++ +++
PC +++ + +++ +++
1 RC = regenerated cellulose; CA = cellulose acetate; ME = mixed ester; CN = cellulose nitrate; PVDF = polyvinylidene fluoride; PP = polypropylene; NYL = nylon; PES = polyethersulfone; PTFE = Polytetrafluoroethylene; PC = polycarbonate.
+++ strong characteristic
+ weak characteristic
- does not have characteristi

The regenerated cellulose family

RC Membrane

Mobile phase filtration

RC_Membrane

Whatman RC55 and GV 050/2 vacuum filtration unit for solvent filtration

Use the same material for mobile phase filtration and sample filtration to:

  • Reduce variation of analysis
  • Reduce rate of column clogging
  • Enhance lifetime of column
If inline degassing is required, consider the Whatman Inline filter/de-gasser. Choose from two membrane options:
  • Nylon – when mobile phase is > 20% aqueous
  • Polypropylene – for non-aqueous solvents
Puradisc Filters

Preventive care: Puradisc filters

Filtration of your samples is important as a preventive maintenance step for HPLC or UHPLC analysis. Keep unwanted particulate matter from entering the injector to increase column life, shorten run time, and optimize peak shape.

  • Manufactured to a high standard in GE’s ISO 9001:2008 certified facilities
  • RC available in 13 mm and 25 mm diameters; hold-up volume < 25 μL for 13 mm and < 100 μL for 25 mm
  • Available in non-RC membrane types to support a variety of other applications
Puradisc_Filters

Typical data

Puradic Syringe Filters

 

4 mm diameter*

13 mm diameter

25 mm diameter

30 mm diameter*

Housing Polypropylene Polypropylene Polypropylene Polycarbonate
Filtration area 0.2 cm2 1.3 cm2 4.2 cm2 5.7 cm2
Maximum pressure 75 psi (5.2 bar) 75 psi (5.2 bar) 75 psi (5.2 bar) 100 psi (6.9 bar)
Volume ‘hold up’ with air purge < 10 μl < 25 μl < 100 μl < 50 μl
Dimensions 10.1 × 23.5 mm
19.5 × 7.7 mm
(PVDF membrane only)
16.3 × 19.8 mm 22.9 × 28.4 mm 26 × 34 mm
Weight (approx) 0.55 g 0.95 g 2.7 g 4.7 g
Volume throughput up to 2 ml up to 10 ml up to 100 ml up to 100 ml
Inlet connection Female Luer lock Female Luer lock Female Luer lock Female Luer lock
Outlet connection Male Luer/tube tip Male Luer/tube tip Male Luer Male Luer/tube tip
Sterilization§ Autoclave at 121°C Autoclave at 121°C+ Autoclave at 121°C Autoclaving not recommended
* Diameters available for Puradisc only.
Data the same for Puradisc and Uniflo, except: Uniflo filtration area = 0.65 cm2; Max pressure = 67.5 psi (4.7 bar); Volume hold up is < 50 μl; dimensions = 19.6 × 16.9 mm
Data the same for Puradisc and Uniflo, except: Uniflo filtration area = 4.9 cm2; Max pressure = 67.5 psi (4.7 bar); dimensions = 24.5 × 29.2 mm
§ Applies to nonsterile filters only. Do not autoclave sterile filters
Spartan Filters

Certified quality for method development: SPARTAN filters

Spartan_Filters

SPARTAN brand syringe filters are HPLC-certified for confidence and consistent results. Tested and certified for the absence of UV-absorbing substances (210 and 254 nm) with water, methanol, acetonitrile to ensure absence of interfering substances.

  • Hydrophilic, low protein-binding membrane made of regenerated cellulose
  • Excellent chemical resistance against the standard aqueous and organic HPLC solvents
  • Tested and certified for the absence of UV-absorbing substances at wavelengths of 210 and 254 nm with water, methanol, and acetonitrile
  • 13 mm diameter with Mini-Tip options
  • 13 mm diameter with extremely low dead volume < 10 μL
Whatman GDX

High-particulate, challenging sample filtration: Whatman GD/X filters

Whatman_GDX

Filter even the most difficult samples and use less hand pressure with GD/X syringe filters.

  • Exceptional loading capacity and fast flow rates – prevents back pressure and clogging of membrane
  • Graduated microfiber prefilter from 1 μm to 0.7 μm
  • Higher flow rates (3×) compared to unprotected membranes
  • Uses glass microfiber-based prefilters
For metals testing and other applications where glass-based compounds could interfere with analysis, we offer a related syringe filter (GD/XP), which uses polypropylene prefilters.

Typical data

Whatman GD/X Syringe Filters

Membrane

GD/X 13 mm

GD/X 25 mm

Housing Polypropylene (pigment-free) Polypropylene (pigment-free)
Filtration area 1.3 cm2 4.6 cm2
Maximum pressure 100 psi (6.9 bar) 75 psi (5.2 bar)
Volume “hold-up” full housing with air purge 0.5 ml 50 μl (approx) 1.4 ml 250 μl (approx)
Dimensions 21.6 × 29.8 mm 20.8 × 29.8 mm
Weight 3 g (approx) 3 g (approx)
Flow direction Flow should enter from the inlet Flow should enter from the inlet
Inlet connection Female Luer lock Female Luer lock
Outlet connection Male Luer Male Luer
Sterilization* Autoclave at 121°C at 15 psi for 20 min Autoclave at 121°C at 15 psi for 20 min
Glass microfiber prefiltration media 100% borosilicate GMF 150: 1 μm GF/F 0.7 μm 100% borosilicate GMF 150: 1 μm GF/F 0.7 μm
* Applies to nonsterile filters only. Do not autoclave sterile GD/X filters.

Typical data

GD/XP Syringe Filters

 

GD/XP 13 mm

Housing Polypropylene (pigment-free)
Filtration area 4.6 cm2
Maximum pressure 75 psi (5.2 bar)
Volume “hold-up” full housing 1.4 ml with air purge 250 μl (approx)
Dimensions 20.8 × 29.8 mm
Weight 3 g (approx)
Flow direction Flow should enter from the inlet
Inlet connection Female Luer lock
Outlet connection Male Luer
Sterilization Autoclave at 121°C at 15 psi for 20 min
Prefiltration media PP 20 μm: 5 μm
Not recommended for nylon.
Whatman_GDX_Diagram
Mini-UniPrep™

Autosampler and workflow support: Mini-UniPrep filters

Whatman Mini-UniPrep Syringeless Filters - polypropylene or glass chambers

Mini_UniPrep

The Mini-UniPrep syringeless filters are compatible with most autosamplers.

  • Easy-to-use design supports sample preparation outside of the lab if needed
  • Process samples in one-third the time of traditional syringe filtration
  • Replaces syringe, syringe filter, vial, and cap in one consumable
  • Polypropylene or glass chamber options to prevent interference from chemical leaching
  • Amber vials available for light sensitive samples
  • Multi-compressors available for ease of use
  • 12 × 33 mm vial can be used to filter up to 400 μL
Mini_UniPrep_Parts

Typical data

Mini-UniPrep and Mini-UniPrep G2 filter vials

 

Mini-UniPrep

Mini-UniPrep G2

Dimensions Equivalent in size to 12 mm × 32 mm vials Equivalent in size to 12 × 32 mm vials
Materials of construction    
Chamber: Polypropylene Borosilicate glass
Plunger housing: Polypropylene Polypropylene
Plunger inner storage vial N/A Borosilicate glass/td>
Filter medium: As specified As specified
Septum: Silicone with PTFE liner Silicone with PTFE liner
Cap: Polypropylene Polypropylene
Maximum operating temp 50°C (122°F) 50°C (122°F)
Max. unfiltered sample capacity 400 μL 500 μL
Max. filtered sample capacity 350 μL 330 μL
Dead volume 50 μL 170 μL
Recommended minimum filtering volume 100 μL 220 μL placed in the chamber to obtain 50 μL in inner storage vial
Nominal force needed to compress Approx. 8.2 kg (18 lbs) Approx. 11.3 kg (25 lbs)
Autosampler needle height adjustment: 3 mm from the bottom of Mini-UniPrep 5 mm from the bottom of Mini-UniPrep G2
Autosampler compatibility Any autosampler that accommodates standard 12 × 32 mm profile vials Any autosampler that accommodates standard 12 × 32 mm profile vials
Resources Request your sample