MACHEREY-NAGEL – Products for thin layer chromatography (TLC/HPTLC)

Macherey-Nagel Macherey-Nagel

MACHEREY-NAGEL and Chromatography

We provide optimal and reliable solutions for your laboratory work in sample preparation, method development and routine analysis.

About Us

MACHEREY-NAGEL Chromatography – complete solutions for your analysis

From a pioneer in chromatography to a full-range supplier of laboratory consumables, we supply laboratories around the world with HPLC, GC and SPE columns, TLC/HPTLC plates, autosampler vials, closures and more.

Macherey-Nagel image Macherey-Nagel image

MACHEREY-NAGEL offers a versatile range of ready-to-use TLC and HPTLC layers, which are the result of 50 years of continuous research and development in thin layer chromatography.


The comprehensive range of TLC products from MACHEREY-NAGEL includes:

Macherey-Nagel

TLC/HPTLC glass plates

ADAMANT, SIL G or SIL HD are silica layers on glass backing. It’s hard to imagine a laboratory without our reliable TLC and HPTLC glass plates.

Macherey-Nagel

ALUGRAM and POLYGRAM TLC/HPTLC sheets are easy to handle, lightweight and flexible.

High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results. Moreover these TLC sheets are easy to cut with scissors.

Macherey-Nagel

Accessories

In addition to high quality TLC plates and sheets, we offer staining reagents and developing chambers, as well as introductory sets for educational purposes.

TLC Backings & Supports
Macherey-nagel Macherey-nagel

TLC/HPTLC plates and sheets consist of an adsorbent stationary phase on a backing support.

MACHEREY-NAGEL offers three different backings:
 

  • Glass plates
  • Aluminium sheets
  • Polyester sheets

Properties of TLC backings

Glass Plates

  • Thickness (approx.): 1.3mm
  • Weight and storage requirements: high
  • Torsional strength: ideal
  • Temperature stability: high
  • Susceptible to breakage: yes
  • Can be cut with scissors: no
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: depends on phases (layer)

Glass plates are robust, heat proof and chemically resistant to all common mobile phases and visualisation reagents. They are the traditional option in TLC/HPTLC and are widely used in the pharmaceutical sector and other laboratory environments.


Aluminium Sheets - ALUGRAM Xtra

  • Thickness (approx.): 0.15mm
  • Weight and storage requirements: low
  • Torsional strength: relatively high
  • Temperature stability: high
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: low
  • Suitability for aqueous detection reagents: ALUGRAM: low to moderate, ALUGRAM Xtra: moderate to high

Aluminium sheets are easy to handle, lightweight and flexible. High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results, even with 100% aqueous detection reagents. Moreover, ALUGRAM Xtra sheets are easy to cut with scissors. No flaking of silica occurs!


Polyester Sheets – POLYGRAM

  • Thickness (approx.): 0.2mm
  • Weight and storage requirements: low
  • Torsional strength: low
  • Temperature stability: maximum 185°C
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: good

Polyester sheets are easy to handle, lightweight and flexible, and can also be cut with scissors. Developed POLYGRAM sheets can also be stored for documentation in laboratory notebooks.

TLC and HPTLC
Macherey_Nagel

Features of modern TLC/HPTLC

The success of thin layer chromatography as a highly efficient microanalytical separation method is based on a large number of advantageous properties:

  • High sample throughput in a short time
  • Suitable for screening tests
  • Pilot procedure for HPLC and Flash chromatography
  • After separation the analytical information can be stored for a longer period of time (the TLC ready-to-use layer acts as storage medium for data)
  • Separated substances can be subjected to subsequent analytical procedures (e.g., IR, MS) at a later date
  • Rapid and cost-efficient optimisation of the separation due to easy change of mobile and stationary phase
Macherey-nagel Macherey-nagel

'TLC' and 'HPTLC' are both widely used terms in laboratory environments, but what is the difference? At MACHEREY-NAGEL, we define 'HPTLC' where at least one of the following criteria is being fulfilled:

  • Layers with particle size 2–10 μm
  • Layers prefixed with 'Nano'
  • Modified layers

Narrow fractionation of HPTLC silica particles allows:

  • Sharper separations
  • Shorter developing times
  • Shorter migration distances
  • Smaller samples needed
  • Increased detection sensitivity (compared to TLC)
Products

Macherey-Nagel™ RNaseA

Intended primarily for use with NucleoSpin™ and NucleoBond™ kits. Macherey-Nagel™ RNase A is a freeze-dried enzyme sourced from bovine pancreas. It has RNase activity of 120 U/mg. Available in 50mg and 100mg packs. 50 MG RNASE A 50MG STORE AT 4-8C

Macherey-Nagel™ Quantofix™ Sulfate Test Strip Kits

Allows for the quick and easy determination of sulfate in solutions. Macherey Nagel™ Quantofix™ Sulfate Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Sulfate semi, quantitat

Macherey-Nagel™ Chromafix™ PS-H+ SPE Cartridge

For removal or concentration of cations from water, decreasing the pH value of basic samples for standard protocol. Macherey-Nagel™ Chromafix™ PS-H+ SPE Cartridge is a polymer-based SPE phase for RP and ion chromatography. X50 Solid Phase Extraction Cartridges CHROMAFIX PS-H+ (L) average content of sorbent: 900 mg

Macherey-Nagel™ TMSH

TMSH, 0,2 M, 10x1 ml

Macherey-Nagel™ Chromafix™ C18 ec Cartridge

Festphasenextraktionskartuschen CHROMAFIX 900-C18ec Füllmenge: 900 mg, (VE=50 St.)

Macherey-Nagel™ Chromabond™ Leur Fitting

X12 CHROMABOND Luer fitting with lid female for Vacuum manifold,

Macherey-Nagel™ Porafil Nitrocellulose Membrane Filter

PORAFIL Membranfilter NC,weiß,Por.0,45µm, D=50 mm(VE=50Stck.)

Macherey-Nagel™ Quantofix™ Peroxide 1000 Test Strip Kits

Allows for the quick and easy determination of peroxide levels in solutions. Macherey Nagel™ Quantofix™ Peroxide 1000 Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Peroxide 1000 semi,

Macherey-Nagel™ Aluminum Oxide, 90 Neutral

Aluminiumoxid 90 neutral,Aktivitätsstufe I0,05-0,2 mm, 1 kg

Macherey-Nagel™ Quantofix™ Cyanide Semi-quantitative Test Strips

Convenient: ready to use kits, pre-calibrated, contain all necessary equipment and reagents X100 QUANTOFIX CYANIDE

Macherey-Nagel™ LIPODEX™ E Capillary Columns for GC

Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ E Capillary Columns for GC are phases with eight γ-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase. FS capillary column LIPODEX E ID: 0,1 mm, length:10 m

Macherey-Nagel™ MN 615 ff Grade Filter Papers, Folded

Particularly suited for fat analysis (e.g. using the Weibull-Stoldt method). Macherey-Nagel™ MN 615 ff Grade Filter Papers, Folded are smooth qualitative papers washed with organic solvents to guarantee that these filters are practically free of fats and resins. Faltenfilter MN 615 ff 1/4, D=27 cm (VE=100Stck.)

Macherey-Nagel™ MN 615 Grade Filter Papers, Round

Particularly suited for general laboratory filtrations. Macherey-Nagel™ MN 615 Grade Filter Papers, Round is a smooth qualitative paper with medium fast filtration speed. The average ash content is about 0.1%, and the amount of α-cellulose is about 95%. X100 QUALITATIVE FILTER 615 45CM

Macherey-Nagel™ Xtra SIL G Silica Layers on Alugram™ Aluminum Sheets UV254

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Xtra SIL G Silica Layers on Alugram™ Aluminum Sheets UV254 come in a variety of sizes. X50 ALUGRAM Xtra-Sheets SIL G/UV254 size: 4 x 8 cm

Macherey-Nagel™ Vacuum Gauge

For use with vacuum manifolds CHROMABOND Vacuum gauge complete with accessories

Macherey-Nagel™ NucleoSpin™ Gel and PCR Clean-up Kit

Clean up PCR reactions and gel extractions with a two-in-one approach. Macherey-Nagel™ NucleoSpin™ Gel and PCR Clean-up Kit is optimized for recovery and elution volume when purifying DNA fragments via both applications. NucleoSpin Gel and PCR Clean-up (250)

Macherey-Nagel™ Quantofix™ Peroxide 100 Test Strip Kits

Allows for the quick and easy determination of peroxide levels in solutions. Macherey Nagel™ Quantofix™ Peroxide 100 Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Peroxide 100 semi,

Macherey-Nagel™ Nucleosil™ 100-5 C18 HD CC Guard Columns Cartridges

X3 GUARD CARTRIDGE NUCLEOSIL C18 HD 5µM 4MM ID(pack of 3)

Macherey-Nagel™ Crimp Neck Vials, N11, Clear

Store material for use in chromatography. Macherey-Nagel Crimp Neck Vials, N11, Clear are hydrolytic glass vials with 11mm crimp neck closures. Vials are manufactured under strict hygienic conditions to ensure high quality for a safe analysis. Packaged in 100 vials per polypropylene box. Probengläser N 11-1 CG, farblos, mit Rollrand(VE=100Stck.)

Macherey-Nagel™ MN 617 Grade Filter Papers, Folded

Suited for general filtration applications, including coarse-crystalline qualitative analysis. Macherey-Nagel™ MN 617 Grade Filter Papers, Folded are smooth, soft filter papers with fast filtration speed. The average ash content is about 0.1%, the amount of α-cellulose is about 95%. X100 FILTER PAPER D24MM

Macherey-Nagel™ NucleoBond™ AX 500 Columns

High-copy plasmids from E. coli, Low-copy plasmids from E. coli 1 SET NUCLEOBOND AX 500, 10 COLUMNS FOR THE ISOLATion of plasmid DNA, buffers not included, plastic

Macherey-Nagel™ LIPODEX™ A Capillary Columns for GC

Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ A Capillary Columns for GC are phases with six α-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase. FS capillary column LIPODEX A ID: 0.25 mm, length: 25 m

Macherey-Nagel™ MN 619 de Grade Filter Paper, Folded

Suited for ultra-fine qualitative filtration applications. Macherey-Nagel™ MN 619 de Grade Filter Papers, Folded (= No. 5) are smooth, extra dense filter papers with very slow filtration speed. The average ash content is about 0.1%, the amount of α-cellulose is about 95%. Faltenfilter MN 619 de 1/4, D=18,5 cm (VE=100Stck.)

Macherey-Nagel™ Developing Chamber

X4 Development chamber 4

Macherey-Nagel™ Optima™ 5 Amine GC Capillary Column

Capillary column OPTIMA-5 AM ID: 0.32 mm, film thickness: 0.25 µm lenght: 30 m,

Macherey-Nagel™ Chromabond™ C4 Polypropylene SPE Column

X50 CHROMABOND columns C4 volume: 3 mL, content of sorbent: 500 mg material: PP

Macherey-Nagel™ MN 640 de Grade Ashless Filter Papers, Round

Acid-washed with an extremely low ash content of <0.01% for quantitative analysis and gravimetric applications. Macherey-Nagel™ MN 640 de Ashless Filter Papers, Round are smooth-surface filter papers that perform very slow filtrations of very fine particulates. Rundfilter MN 640 de, D=7 cm (VE=100Stck.)

Macherey-Nagel™ Wash Buffer MBL3 for NucleoMag™ Blood

Additional wash buffer for use with NucleoMag™ Blood 200 μ/3 mL kits for magnetic-bead based isolation of genomic DNA from whole blood and biological fluids. Buffer MBL3 (1000 mL)

Macherey-Nagel™ Optima™ 240 GC Capillary Column

Capillary column OPTIMA-240 ID: 0.32 mm, film thickness: 0.35 µm length: 30 m,

Macherey-Nagel™ MN 616 Grade Filter Papers, Folded

Particularly suited for general laboratory filtrations. Macherey-Nagel™ MN 616 Grade Filter Papers, Folded is a smooth qualitative paper with medium fast filtration speed. The average ash content is about 0.1%, and the amount of α-cellulose is about 95%. Faltenfilter MN 616 1/4, D=32 cm (VE=100Stck.)

  spinner