La - Mz Restriction Enzymes

Thermo Scientific™ FastDigest MluI

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Invitrogen™ Anza™ 24 MssI

Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System.

Thermo Scientific™ Mva1269I (BsmI) (10 U/µL)

The Mva1269I (BsmI) restriction enzyme recognizes GAATGC(1/-1)^ sites and cuts best at 37°C in R buffer (Isoschizomers: BsaMI, BsmI, PctI).

Thermo Scientific™ MboII (5 U/µL)

The MboII restriction enzyme recognizes GAAGA(8/7)^ sites and cuts best at 37°C in B buffer.

Thermo Scientific™ FastDigest MlsI

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Thermo Scientific™ FastDigest MboII (IIs class)

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Thermo Scientific™ FastDigest MssI

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Thermo Scientific™ MlsI (MscI) (5 U/µL)

The MlsI (MscI) restriction enzyme recognizes TGG^CCA sites and cuts best at 37°C in R buffer (Isoschizomers: BalI, MluNI, MscI, Msp20I).

Thermo Scientific™ MreI (Sse232I) (10 U/µL)

Cut at CG^CCGGCG sites with MreI (Sse232I) restriction enzyme, which performs best at 37°C in G buffer.

Thermo Scientific™ Mph1103I (NsiI) (10 U/µL)

The Mph1103I (NsiI) restriction enzyme recognizes ATGCA^T sites and cuts best at 37°C in R buffer (Isoschizomers: EcoT22I, NsiI, Zsp2I).

Thermo Scientific™ MvaI (BstNI) (10 U/µL)

Cut at CC^WGG sites with MvaI (BstNI) restriction enzyme, which performs best at 37°C in R buffer (Isoschizomers: AjnI, BseBI, Bst2UI, BstNI, BstOI, Psp6I, PspGI).

Thermo Scientific™ MauBI (5 U/µL)

Cut T CG^CGCGCG sites with MauBI restriction enzyme, which performs best at 37°C in Tango buffer.

Thermo Scientific™ MnlI (10 U/µL)

The MnlI restriction enzyme recognizes CCTC(7/6)^ sites and cuts best at 37°C in G buffer.

Thermo Scientific™ LguI (SapI) (5 U/µL)

The LguI (SapI) restriction enzyme recognizes GCTCTTC(1/4)^ sites and cuts best at 37°C in Tango buffer (Isoschizomers: BspQI, PciSI, SapI).

Thermo Scientific™ MspI (HpaII) (10 U/µL)

The MspI (HpaII) restriction enzyme recognizes C^CGG sites and cuts best at 37°C in Tango buffer.

Invitrogen™ Anza™ 95 MauBI

Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System.

Invitrogen™ Anza™ 89 Mva1269I

Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System.

Thermo Scientific™ FastDigest MnlI (IIs class)

The FastDigest MnlI restriction enzyme recognizes CCTC(7/6)^ sites and cuts best at 37°C in 5-15 minutes using universal FastDigest Buffer.

Invitrogen™ Anza™ 104 MboII

Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System.

Invitrogen™ Anza™ 85 MreI

Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System.

Thermo Scientific™ MbiI (BsrBI) (10 U/µL)

Cut at CCGCTC(-3/-3)^ sites with MbiI (BsrBI) restriction enzyme, which performs best at 37°C in Tango buffer (Isoschizomers: AccBSI, BsrBI).

Thermo Scientific™ FastDigest SchI

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Invitrogen™ Anza™ 10 DpnI

Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System.

Thermo Scientific™ FastDigest MspI

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Thermo Scientific™ LweI (SfaNI) (10 U/µL)

The LweI (SfaNI) restriction enzyme recognizes GCATC(5/9)^ sites and cuts best at 37°C in Tango buffer (Isoschizomers: SfaNI).

Thermo Scientific™ MssI (PmeI) (5 U/µL)

The MssI (PmeI) restriction enzyme recognizes GTTT^AAAC sites and cuts best at 37°C in B buffer (Isoschizomers: PmeI).

Invitrogen™ Anza™ 28 MluI

Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System.

Thermo Scientific™ FastDigest SaqAI

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Thermo Scientific™ FastDigest Mva1269I (IIs class)

Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer.

Thermo Scientific™ MunI (MfeI) (10 U/µL)

The MunI (MfeI) restriction enzyme recognizes C^AATTG sites and cuts best at 37°C in G buffer (Isoschizomers: MfeI).

  spinner