Learn More
Thermo Scientific™ Pierce™ HA-Tag Magnetic IP/Co-IP Kit
Perform immunoprecipitation (IP) assays of HA-tagged proteins or co-IP reactions with HA-tagged bait proteins with these magnetic beads, positive control and reagents.
Brand: Thermo Scientific™ 88838
Code : PN
Additional Details : Weight : 0.45360kg
Description
Perform immunoprecipitation (IP) assays of HA-tagged proteins or co-IP reactions with HA-tagged bait proteins with the magnetic beads, positive control and reagents provided in the Thermo Scientific™ Pierce Magnetic IP/Co-IP Kit.
Additional Information and Online Ordering »
Highlights:
Specific – highly specific anti-HA monoclonal antibody enables high yields of immunoprecipitation products
Fast – Optimized protocol is completed in approximately 1 hour
Low non-specific binding – stable, pre-blocked beads provide highly purified HA-tagged proteins
Versatile – beads are compatible with manual and automated workflows (e.g., Thermo Scientific™ KingFisher Instruments)
Convenient and easy – complete kit includes all necessary reagents and easy-to-follow instructions
Includes:
The kit contains magnetic beads immobilized with anti-HA antibody, lysis/wash buffer, low pH elution buffer, neutralization buffer, HA-tag positive control lysate, and non-reducing sample buffer.
Recommended for:
High-throughput immunoprecipitation of recombinant HA-tagged proteins and co-IP of interacting proteins
Specifications
Sufficient For: 40 IP reactions using 25 μL of anti-HA magnetic beads • HA-tagged Positive Control (Part No. 26180X), 500 μL • Pierce Anti-HA Magnetic Beads, 1 mL • Pierce IP Lysis/Wash Buffer, 2 × 50 mL • Non-Reducing Sample Buffer (5X), 5 mL • Elution Buffer (pH 2.0), 5 mL • Neutralization Buffer (pH 8.5), 1 mL HA-tagged Positive Control ships separately—store at -70°C. Store remaining components at 4°C. |
|
KingFisher™ Flex, Magnetic Stand | |
1 Kit | |
Target-Specific | |
40 Reactions |
Affinity Purification | |
Pierce™ | |
Pull-Down (Tag-Based), Immunoprecipitation (IP) | |
Tag IP/Co-IP Kit | |
Kit |
Safety and Handling
- Pierce HA-Tag Magnetic IP/CoIP Kit
Signal Word
- Warning
Hazard Category
- Serious eye damage/eye irritation Category 2
- Skin corrosion/irritation Category 2
Hazard Statement
- H315-Causes skin irritation.
- H319-Causes serious eye irritation.
Precautionary Statement
- P264-Wash hands thoroughly after handling.
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Supplemental information
- MIXTURE LIST-Contains : hydrogen chloride
For Research Use Only. Not for use in diagnostic procedures.