Electrophoresis
Invitrogen™ Novex™ SeeBlue™ Plus2 Pre-stained Protein Standard
Allows you to easily visualize protein molecular weight ranges during electrophoresis and quickly evaluate Western transfer efficiency
Invitrogen™ Novex™ SimplyBlue™SafeStain
Less hazardous and does not require methanol or acetic acid fixatives or destains
Invitrogen™ Novex™ HiMark™ Pre-stained Protein Standard
Designed for analysis of high molecular weight proteins on NuPAGE™ Novex™ Tris-Acetate gels
Fisherbrand™ omniPAGE WAVE Maxi Vertical Electrophoresis Modular System
Allows multiple electrophoresis techniques to be performed in the same unit.
Invitrogen™ NuPAGE™ 10% Bis-Tris, 1.0 mm, Mini Protein Gel, 15-well
Separation Range: 3.5 to 260 kd; Separation Type: Denaturing (MES Running Buffer, MOPS Buffer); For Use With: Mini Gel Tank, XCell SureLock Mini
Thermo Scientific™ PageRuler™ Plus Prestained 10-250kDa Protein Ladder
Mixture of 9 blue-, orange- and green-stained proteins (10 to 250kDa) used as size standards in protein electrophoresis (SDS-PAGE) and Western blotting.
Invitrogen™ Novex™ DryEase™ Mini Cellophane
Component of DryEase Mini-Gel Drying System
Invitrogen™ Mini Gel Tank
Compatible with a variety of Novex™ gels, NuPAGE™ gels, and Bolt™ Bis-Tris Plus gels
Invitrogen™ SureCast™ Gel Handcast Bundle A - Hardware and Reagents
Pour your own polyacrylamide gels easily and confidently with a SureCastâ„¢ Gel Handcast Bundle A. The SureCast Handcast System can be used to create polyacrylamide gels using SureCast Handcast Reagents as well as any other popular polyacrylamide gel casting reagents.
Invitrogen™ Bolt™ 4 to 12% Bis-Tris, 1.0 mm, Mini Protein Gel, 10-well
Separation Range: 3.5 to 260 kd; Separation Type: Denaturing (MES Running Buffer, MOPS Buffer); For Use With: Mini Gel Tank, XCell SureLock Mini
Thermo Scientific™ PageRuler™ Prestained 10-180kDa Protein Ladder
Mixture of 10 blue-, orange- and green-stained proteins (10 to 180kDa) used as size standards in protein electrophoresis (SDS-PAGE) and Western blotting.
Thermo Scientific™ Pierce™ Unstained Protein Molecular Weight Marker
A mixture of seven native proteins (14.4kDa to 116kDa) for use as size standards in protein electrophoresis (SDS-PAGE).
Invitrogen™ Novex™ iBlot™ 2 Nitrocellulose Transfer Stacks
Used to transfer proteins with the iBlot 2 Gel Transfer Device
Invitrogen™ Novex™ Bolt™ Vertical Mini Blot Module
Wet transfer device used exclusively with the Bolt Minigel Tank
Thermo Scientific™ PageRuler™ Unstained Protein Ladder
A mixture of seven native proteins (14.4 to 116kDa) for use as size standards in protein electrophoresis (SDS-PAGE).
Invitrogen™ Bolt™ 4 to 12% Bis-Tris, 1.0 mm, Mini Protein Gel, 15-well
Separation Range: 3.5 to 260 kd; Separation Type: Denaturing (MES Running Buffer, MOPS Buffer); For Use With: Mini Gel Tank, XCell SureLock Mini
Invitrogen™ iBlot™ 2 Gel Horizontal Transfer Device
Performs Western blotting transfer simply, efficiently, and reliably, within seven minutes and without the need for liquid buffers
Invitrogen™ NuPAGE™ 4 to 12% Bis-Tris, 1.0 mm, Mini Protein Gel, 17-well
Separation Range: 3.5 to 260 kd; Separation Type: Denaturing (MES Running Buffer, MOPS Buffer); For Use With: Mini Gel Tank, XCell SureLock Mini
Invitrogen™ NuPAGE™ 4 to 12% Bis-Tris, 1.0 mm, Midi Protein Gel, 12 + 2-well
Separation Range: 3.5 to 260 kd; Separation Type: Denaturing (MES Running Buffer, MOPS Buffer); For Use With: Midi Gel Tank, XCell4 SureLock Midi
GE Healthcare Protein and Peptide Molecular Weight Markers
Run these markers to determine the molecular weight of uncharacterized protein samples with precision. GE Healthcare Life Sciences™ Protein and Peptide Molecular Weight Markers work by comparing unknowns with carefully selected standards.
Hoefer™ Glass Plates for SE 600 Chroma, SE 600 Standard, or SE 400 Vertical Electrophoresis Units
Accessory parts for SE 600 Chroma SE 600 Standard or SE 400 Vertical Electrophoresis Units
Invitrogen™ Novex™ SilverXpress™ Silver Staining Kit
Staining is complete in a little over one hour
Invitrogen™ Novex™ Sharp Pre-stained Protein Standard
Designed for accurate, easy, and convenient molecular weight estimation of a wide range of molecular weight proteins during SDS-PAGE and Western blotting
Invitrogen™ Novex™ 20X Bolt™ MES SDS Running Buffer
Optimized for use with Bolt™ Bis-Tris Plus gels, and are available in a variety of formats
Invitrogen™ Novex™ Power Supply Adapters
Connect to a variety of electrophoresis units
Invitrogen™ Molecular Probes™ SYPRO™ Orange Protein Gel Stain (5,000X Concentrate in DMSO)
Fast, one-step staining protocol requiring no destaining
Invitrogen™ Novex™ Mark12™ Standard, Unstained
Allows the closest estimation of molecular weight of your sample protein over a wide molecular weight range
Invitrogen™ Novex™ Colloidal Blue Staining Kit
Five times more sensitivity than Coomassie™ R-250— and can detect as little as 10ng of BSA
Invitrogen™ NuPAGE™ 4 to 12% Bis-Tris, 1.0 mm, Midi Protein Gel, 20-well
Separation Range: 3.5 to 260 kd; Separation Type: Denaturing (MES Running Buffer, MOPS Buffer); For Use With: Midi Gel Tank, XCell4 SureLock Midi