Autoclaving, Sterilisation and Lab Washers
Branson Ultrasonics™ Bransonic™ ultrasoon bad, MH-serie
Voorzie uw laboratorium van een industriële klassieker. Branson ultrasone tafelmodelreinigers bieden een uiterst stevige constructie plus een hightechontwerp en verschaffen u jarenlang betrouwbaar gebruik.
TMC Hallcrest™ Thermax Chillchecker Temperature Indicators
Provide an irreversible identification for temperature controled issues. TMC Hallcrest™ Thermax Chillchecker Temperature Indicators can be used for transporation and storage of goods applications.
Thermographic™ Thermax™ stroken voor temperatuurmeting
Measure and be aware of the current temperature with Thermographic™ Thermax™ Temperature Measurement Strips. The temperature label can vary to reflect the heat level needed for monitoring adherence to a required sterilization environment.
Smeg™ Glassware GW4060S Washer with Drying System and Steam Condenser
Used for antibacterical thermal disinfection. Smeg Instruments Laboratory Glassware GW4060S Washer with Drying System and Steam Condenser has electronic door lock system for user safety.
Smeg™ Laboratory Glassware Washer
Clean a wide range of glassware with this washer. Smeg™ Laboratory Glassware Washers are manufactured with high quality materials and feature faultless, intuitive performance. Specific accessories ensure high quality washing of even the most difficult and dirtier instruments.
Smeg™ Glassware GW1160S Basic Washer
Used for antibacterical thermal disinfection. Smeg Instruments Laboratory Glassware GW1160S Basic Washer has electronic door lock system for user safety.
Fisherbrand™ Glass Beaker with Cover
The Fisherbrand™ Glass Beaker with Cover is an ideal accessory for the Fisherbrand™ 11211 ultrasonic cleaner. This is a safe and economical choice for any laboratory.
Corning™ Gosselin™-blenderzakken, geschikt voor autoclaaf
Voor het veilig autoclaveren van besmette producten
Corning™ Autoclave Bags Printed with Biohazard Logo
Used for contaminated waste disposal in autoclave. Gosselin™ Autoclave Bags Printed with Biohazard Logo can withstand autoclaving temperatures up to 134°C/273.2°F.
Smeg™ Universal Basket
Used with standard baskets CS1-1 and CS2 . Smeg Instruments Universal Basket is used with trolley LM20.
Smeg™ Glassware GW1160S Basic Washer
Used for antibacterical thermal disinfection. Smeg Instruments Laboratory Glassware GW1160S Basic Washer has electronic door lock system for user safety.
Smeg™ Glassware GW4060 Washer with Drying System
Used for antibacterical thermal disinfection. Smeg Instruments Laboratory Glassware GW4060 Washer with Drying System has electronic door lock system for user safety.
Branson Ultrasonics™ CPX Series Ultrasonic Cleaning Bath
Outfit your lab with a classic tabletop cleaner, offering high-tech design, solid construction and featuring reliable digital controls with power tracking capabilities.
Branson Ultrasonics™ CPXH Series Ultrasonic Cleaning Bath
Rust uw laboratorium uit met een industriële, klassieke, verwarmde reiniger die dezelfde ultrasone kracht biedt, ook als laadcondities veranderen. Daarnaast bieden Branson ultrasone tafelmodelreinigers van de CPXH-serie een uiterst stevige constructie plus een hightechontwerp en verschaffen ze u jarenlang betrouwbaar gebruik.
Smeg™ Washer Rack
Designed for use with Smeg™ glassware washing devices. Smeg Washer Racks can be used as racks to hold small glass items or as an alternative to the Nylon holding nets.
Miele Professional™ Accessory large washer-disinfector
Fitting kit MVA for installation of the machine without a plinth tray (G7825/G7826)
Miele Professional™ Mobile unit
Module E 945/2 for inserts
Fisherbrand™ Roestvrijstalen mand
Faciliates complete immersion within S-line Ultrasonic Cleaner baths. Fisherbrand™ Immersion Baskets with Handle are manufactured from stainless steel.
Miele Professional™ Conversion kit
Conversion kit UBS 3 for use with selected series G 78 upper baskets in PG 85 machines
Miele Professional™ Dosing system
Dosing cabinet PG 8596 (AE) for the storage of process chemicals and dosing modules
Miele Professional™ Mobile Injector
Mobile unit for optimum loading of pipettes
Miele Professional™ Insert
Insert E 144 for the optimum loading of up to 18 beakers
Miele Professional™ Upper Basket
Upper basket O 800/1 for the optimum loading of different inserts
Miele Professional™ Upper Basket for Narrow Necked Glassware
Upper basket O 187 for the optimum loading of narrow necked glassware
Miele Professional™ Injector Nozzle
Injector nozzles with plastic supports
Fisherbrand™ Sterilisatiepapier, klasse 926
Used as wrap for medical clothes.
Fisherbrand™ Covers for Fisherbrand™ Ultrasonic Cleaners
Voor gebruik met ultrasone reinigers van Fisherbrand
Sterilisers and autoclaves are used in many laboratories, cleanrooms, microbiological facilities and other controlled environments to disinfect a wide range of laboratory consumables and apparatus. Sterilisers may use high pressure, high temperature, chemicals, UV, filtration, or a combination of these methods to eliminate bacteria, fungi, viruses and spores.
What is autoclaving?
Autoclaves are a specific kind of laboratory steriliser. They generate high temperature steam, typically up to 140°C, within a sealed, pressurised loading chamber which can accommodate glassware, plasticware, apparel, equipment and any other items requiring treatment. Prior to loading, objects may first be wrapped inside dedicated autoclave bags or pouches and sealed with special heat-sensitive autoclave sterilisation verification indicator tape that changes colour after successful sterilising conditions have been achieved (typically 20 minutes for most models). Laboratory autoclaves are available as benchtop or floor standing models, with a range of different loading capacities. Most modern autoclaves are also microprocessor controlled, with pre-installed or programmable sterilisation cycles, digital controls, alarms and other safety features. Autoclaves are used for many purposes:
- Sterilisation of glassware, plasticware and other apparatus
- Preparation of sterile cell culture or microbiological growth media
- Sterilisation of surgical instruments or apparel
- Sterilisation of biohazardous laboratory or clinical waste prior to safe and subsequent disposal
Lab washers are designed primarily for cleaning soiled glassware and plasticware, without necessarily certifying sterilisation. They are not normally pressurised, but instead typically rely on hot water sprays or jets and special cleaning liquids for their cleaning action, rather like a domestic dishwasher.